Note
Go to the end to download the full example code
METdbLoad: Brightness Temperature
model_applications/ short_range/ METdbLoad_fcstFV3_obsGoes_BrightnessTemp.conf
Scientific Objective
Load MET data into a database using the met_db_load.py script found in dtcenter/METdataio. Specifically, this use case loads distance map output from grid_stat and mode output into a database.
Datasets
METplus Components
This use case utilizes the METplus METdbLoad wrapper to search for files ending with .stat or .txt, substitute values into an XML load configuration file, and call met_db_load.py. It then loads data into a METviewer database for the following use cases: MODE_fcstFV3_obsGOES_BrightnessTemp, MODE_fcstFV3_obsGOES_BrightnessTempObjs, and GridStat_fcstFV3_obsGOES_BrightnessTempDmap.
METplus Workflow
The METdbload is run once and loads data for two ensemble members, one model initialization time and 2 forecast lead times, listed below.
METplus Configuration
METplus first loads all of the configuration files found in parm/metplus_config, then it loads any configuration files passed to METplus via the command line
[config]
# Documentation for this use case can be found at
# https://metplus.readthedocs.io/en/latest/generated/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp.html
# For additional information, please see the METplus Users Guide.
# https://metplus.readthedocs.io/en/latest/Users_Guide
###
# Processes to run
# https://metplus.readthedocs.io/en/latest/Users_Guide/systemconfiguration.html#process-list
###
PROCESS_LIST = METDbLoad
###
# Time Info
# LOOP_BY options are INIT, VALID, RETRO, and REALTIME
# If set to INIT or RETRO:
# INIT_TIME_FMT, INIT_BEG, INIT_END, and INIT_INCREMENT must also be set
# If set to VALID or REALTIME:
# VALID_TIME_FMT, VALID_BEG, VALID_END, and VALID_INCREMENT must also be set
# LEAD_SEQ is the list of forecast leads to process
# https://metplus.readthedocs.io/en/latest/Users_Guide/systemconfiguration.html#timing-control
###
LOOP_BY = VALID
VALID_TIME_FMT = %Y%m%d%H
VALID_BEG = 2019052100
VALID_END = 2019052112
VALID_INCREMENT = 12H
MET_DB_LOAD_RUNTIME_FREQ = RUN_ONCE
###
# File I/O
# https://metplus.readthedocs.io/en/latest/Users_Guide/systemconfiguration.html#directory-and-filename-template-info
###
MET_DB_LOAD_INPUT_TEMPLATE = {INPUT_BASE}/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp/grid_stat,{INPUT_BASE}/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp/grid_stat_obj,{INPUT_BASE}/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp/mode
###
# METdbLoad Settings
# https://metplus.readthedocs.io/en/latest/Users_Guide/wrappers.html#metdbload
###
MET_DATA_DB_DIR = {METPLUS_BASE}/../METdataio
# XML file with settings for
MET_DB_LOAD_XML_FILE = {PARM_BASE}/use_cases/met_tool_wrapper/METdbLoad/METdbLoadConfig.xml
# If true, remove temporary XML with values substituted from XML_FILE
# Set to false for debugging purposes
MET_DB_LOAD_REMOVE_TMP_XML = True
# connection info
MET_DB_LOAD_MV_HOST = localhost:3306
MET_DB_LOAD_MV_DATABASE = mv_metplus_test
MET_DB_LOAD_MV_USER = root
MET_DB_LOAD_MV_PASSWORD = mvuser
# data info
MET_DB_LOAD_MV_VERBOSE = false
MET_DB_LOAD_MV_INSERT_SIZE = 1
MET_DB_LOAD_MV_MODE_HEADER_DB_CHECK = false
MET_DB_LOAD_MV_DROP_INDEXES = false
MET_DB_LOAD_MV_APPLY_INDEXES = true
#MET_DB_LOAD_MV_GROUP = METplus Input Test
MET_DB_LOAD_MV_GROUP = Testing
MET_DB_LOAD_MV_LOAD_STAT = true
MET_DB_LOAD_MV_LOAD_MODE = true
MET_DB_LOAD_MV_LOAD_MTD = false
MET_DB_LOAD_MV_LOAD_MPR = false
XML Configuration
METplus substitutes values in the template XML configuration file based on user settings in the METplus configuration file. While the XML template may appear to reference environment variables, this is not actually the case. These strings are used as a reference for the wrapper to substitute values.
Note
See the METdbLoad XML Configuration section of the User’s Guide for more information on the values substituted in the file below:
<load_spec>
<connection>
<host>${METPLUS_MV_HOST}</host>
<database>${METPLUS_MV_DATABASE}</database>
<user>${METPLUS_MV_USER}</user>
<password>${METPLUS_MV_PASSWORD}</password>
</connection>
<verbose>${METPLUS_MV_VERBOSE}</verbose>
<insert_size>${METPLUS_MV_INSERT_SIZE}</insert_size>
<mode_header_db_check>${METPLUS_MV_MODE_HEADER_DB_CHECK}</mode_header_db_check>
<drop_indexes>${METPLUS_MV_DROP_INDEXES}</drop_indexes>
<apply_indexes>${METPLUS_MV_APPLY_INDEXES}</apply_indexes>
<group>${METPLUS_MV_GROUP}</group>
<load_stat>${METPLUS_MV_LOAD_STAT}</load_stat>
<load_mode>${METPLUS_MV_LOAD_MODE}</load_mode>
<load_mtd>${METPLUS_MV_LOAD_MTD}</load_mtd>
<load_mpr>${METPLUS_MV_LOAD_MPR}</load_mpr>
<folder_tmpl>{dirs}</folder_tmpl>
<load_val>
<field name="dirs">
${METPLUS_INPUT_PATHS}
</field>
</load_val>
</load_spec>
Running METplus
This use case can be run two ways:
Passing in METdbLoad_fcstFV3_obsGoes_BrightnessTemp.conf followed by a user-specific system configuration file:
run_metplus.py /path/to/METplus/parm/use_cases/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp.conf /path/to/user_system.conf
Modifying the configurations in parm/metplus_config and then passing in METdbLoad_fcstFV3_obsGoes_BrightnessTemp.conf:
run_metplus.py /path/to/METplus/parm/use_cases/model_applications/short_range/METdbLoad_fcstFV3_obsGoes_BrightnessTemp.conf
The former method is recommended. Whether you add them to a user-specific configuration file or modify the metplus_config files, the following variables must be set correctly:
INPUT_BASE - Path to directory where sample data tarballs are unpacked (See Datasets section to obtain tarballs). This is not required to run METplus, but it is required to run the examples in parm/use_cases
OUTPUT_BASE - Path to directory where METplus output will be written. This must be in a location where you have write permissions
MET_INSTALL_DIR - Path to location where MET is installed locally
Example User Configuration File:
[config]
INPUT_BASE = /path/to/sample/input/data
OUTPUT_BASE = /path/to/output/dir
MET_INSTALL_DIR = /path/to/met-X.Y
Expected Output
A successful run will output the following both to the screen and to the logfile:
INFO: METplus has successfully finished running.
Output files are not generated. Rather, data should be available in the METviewer database. The data in the database should include Stat data for two variables and two model ensembles, and mode data.
Keywords
Note
METdbLoadUseCase
ShortRangeAppUseCase
NOAAEMCOrgUseCase
NOAAHWTOrgUseCase
Navigate to the METplus Quick Search for Use Cases page to discover other similar use cases.
sphinx_gallery_thumbnail_path = ‘_static/short_range-METdbLoad_fcstFV3_obsGoes_BrightnessTemp.png’
Total running time of the script: (0 minutes 0.000 seconds)